Symvoulidis P, Jentoft KM, Garcia-Allende PB, Glatz J, Ripoll J, Ntziachristos V (2014)
Publication Type: Journal article
Publication year: 2014
Book Volume: 39
Pages Range: 3919-3922
Journal Issue: 13
DOI: 10.1364/OL.39.003919
The increasing preclinical and clinical utilization of digital cameras for photographic measurements of tissue conditions motivates the study of reflectance measurements obtained with planar illumination. We examine herein a formula that models the total diffuse reflectance measured from a semi-infinite medium using an exponentially decaying source, assuming continuous plane wave epi-illumination. The model is validated with experimental reflectance measurements from tissue mimicking phantoms. The need for adjusting the blood absorption spectrum due to pigment packaging is discussed along with the potential applications of the proposed formulation. © 2014 Optical Society of America.
APA:
Symvoulidis, P., Jentoft, K.M., Garcia-Allende, P.B., Glatz, J., Ripoll, J., & Ntziachristos, V. (2014). Steady-state total diffuse reflectance with an exponential decaying source. Optics Letters, 39(13), 3919-3922. https://doi.org/10.1364/OL.39.003919
MLA:
Symvoulidis, Panagiotis, et al. "Steady-state total diffuse reflectance with an exponential decaying source." Optics Letters 39.13 (2014): 3919-3922.
BibTeX: Download