Cascade registration of micro CT volumes taken in multiple resolutions

Nagara K, Oda H, Nakamura S, Oda M, Homma H, Takabatake H, Mori M, Natori H, Rueckert D, Mori K (2016)


Publication Type: Conference contribution

Publication year: 2016

Journal

Publisher: Springer Verlag

Book Volume: 9805 LNCS

Pages Range: 269-280

Conference Proceedings Title: Lecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics)

Event location: Bern, CHE

ISBN: 9783319437743

DOI: 10.1007/978-3-319-43775-0_24

Abstract

In this paper, we present a preliminary report of a multiscale registration method between micro-focus X-ray CT (micro CT) volumes taken in different scales. 3D fine structures of target objects can be observed on micro CT volumes, which are difficult to observe on clinical CT volumes. Micro CT scanners can scan specimens in various resolutions. In their high resolution volumes, ultra fine structures of specimens can be observed, while scanned areas are limited to very small. On the other hand, in low resolution volumes, large areas can be captured, while fine structures of specimens are difficult to observe. The fusion volume of the high and low resolution volumes will have benefits of both. Because the difference of resolutions between the high and low resolution volumes may vary greatly, an intermediate resolution volume is required for successful fusion of volumes. To perform such volume fusion, a cascade multi-resolution registration technique is required. To register micro CT volumes that have quite different resolutions, we employ a cascade co-registration technique. In the cascade co-registration process, intermediate resolution volumes are used in a registration process of the high and low resolution volumes. In the registration between two volumes, we apply two steps registration techniques. In the first step, a block division is used to register two resolution volumes. Afterward, we estimate the fine spatial positions relating the registered two volumes using the Powell method. The registration result can be used to generate a fusion volume of the high and low resolution volumes.

Involved external institutions

How to cite

APA:

Nagara, K., Oda, H., Nakamura, S., Oda, M., Homma, H., Takabatake, H.,... Mori, K. (2016). Cascade registration of micro CT volumes taken in multiple resolutions. In Hongen Liao, Guoyan Zheng, Su-Lin Lee, Philippe Cattin, Pierre Jannin (Eds.), Lecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics) (pp. 269-280). Bern, CHE: Springer Verlag.

MLA:

Nagara, Kai, et al. "Cascade registration of micro CT volumes taken in multiple resolutions." Proceedings of the 7th International Conference on Medical Imaging and Augmented Reality, MIAR 2016, Bern, CHE Ed. Hongen Liao, Guoyan Zheng, Su-Lin Lee, Philippe Cattin, Pierre Jannin, Springer Verlag, 2016. 269-280.

BibTeX: Download