Feasibility of gadoxetate disodium enhanced 3D T1 MR cholangiography (MRC) with a specific inversion recovery prepulse for the assessment of the hepatobiliary system

Fahlenkamp UL, Adams LC, Boeker SM, Engel G, Minh Huynh Anh , Wagner M, Hamm B, Makowski MR (2018)


Publication Type: Journal article

Publication year: 2018

Journal

Book Volume: 13

Article Number: e0203476

Journal Issue: 9

DOI: 10.1371/journal.pone.0203476

Abstract

Aim To compare the potential of a gadoxetate disodium enhanced navigator-triggered 3D T1 magnetic-resonance cholangiography (MRC) sequence with a specific inversion recovery prepulse to T2-weighted MRCP for assessment of the hepatobiliary system. Materials and methods 30 patients (12 male, 18 female) prospectively underwent conventional navigator-triggered 3D turbo spin-echo T2-weighted MRCP and 3D T1 MRC with a specific inversion pulse to minimise signal from the liver 30 minutes after administration of gadoxetate disodium on a 1.5 T MRI system. For qualitative evaluation, biliary duct depiction was assessed segmen-tally following a 5-point Likert scale. Visualisation of hilar structures as well as image quality was recorded. Additionally, the extrahepatic bile ducts were assessed quantitatively by calculation of signal-to-noise ratios (SNR). Results The advantages of T1 3D MRC include reduced affection of image quality by bowel movement and robust depiction of the relative position of the extrahepatic bile ducts in relation to the portal vein and the duodenum compared to T2 MRCP. However, overall T1 3D MRC did not significantly (p > 0.05) improve the biliary duct depiction compared to T2 MRCP in all segments: Common bile duct 4.1 vs. 4.4, right hepatic duct 3.6 vs. 4.2, left hepatic duct 3.5 vs. 4.1. Image quality did not differ significantly (p > 0.05) between both sequences (3.6 vs. 3.5). SNR measurements for the hepatobiliary system did not differ significantly (p > 0.05) between navigator-triggered T1 3D MRC and T2 MRCP. Conclusions This preliminary study demonstrates that T1 3D MRC of a specific inversion recovery prepulse has potential to complement T2 MRCP, especially for the evaluation of liver structures close to the hilum in the diagnostic work-up of the biliary system in patients receiving gadoxetate disodium.

Involved external institutions

How to cite

APA:

Fahlenkamp, U.L., Adams, L.C., Boeker, S.M., Engel, G., Minh Huynh Anh, ., Wagner, M.,... Makowski, M.R. (2018). Feasibility of gadoxetate disodium enhanced 3D T1 MR cholangiography (MRC) with a specific inversion recovery prepulse for the assessment of the hepatobiliary system. PLoS ONE, 13(9). https://doi.org/10.1371/journal.pone.0203476

MLA:

Fahlenkamp, Ute Lina, et al. "Feasibility of gadoxetate disodium enhanced 3D T1 MR cholangiography (MRC) with a specific inversion recovery prepulse for the assessment of the hepatobiliary system." PLoS ONE 13.9 (2018).

BibTeX: Download