Accuracy of standard clinical 3T prostate MRI for pelvic lymph node staging: Comparison to 68 Ga-PSMA PET-CT

Meissner S, Janssen JC, Prasad V, Diederichs G, Hamm B, Brenner W, Makowski MR (2019)


Publication Type: Journal article

Publication year: 2019

Journal

Book Volume: 9

Article Number: 10727

Journal Issue: 1

DOI: 10.1038/s41598-019-46386-3

Abstract

The aim was to assess the performance of prostate 3T MRI for pelvic lymph node (LN) staging in prostate cancer (PCa), in comparison to 68Gallium-prostate specific membrane antigen PET-CT (68Ga-PSMA PET-CT) as reference standard for LN detection. 130 patients with PCa underwent non-contrast-enhanced multiparametric prostate 3T MRI and 68Ga-PSMA-PET-CT within 180 days at our institution. Overall, 187 LN metastases (n = 43 patients) detected by 68Ga-PSMA-PET-CT were characterized by calculating maximum standardized uptake value (SUVmax), area, diameter and anatomical location including iliac, obturator, presacral and inguinal region. MRI achieved an overall sensitivity, specificity, positive and negative predictive value of 81.6% (CI 71.1–88.9%), 98.6% (CI 97.6–99.2%), 73.5% (CI 52.1–87.6%) and 99.5% (CI 98.8–99.8%), respectively. On a region-based analysis, detection rates differed non-significantly (ps > 0.12) in the anatomical regions. On a size-dependent analysis, detection of LN > 10 mm did not differ significantly (ps > 0.09) from LN ≤ 10 mm. In comparison to single T1 sequence evaluation, additional use of the T2 weighted sequences did not improve the overall performance significantly (p > 0.05). 3T prostate MRI represented an accurate tool for the detection of LN compared to 68Ga-PSMA-PET-CT. Especially for LN metastases smaller than 10 mm, MRI was less accurate compared to 68Ga-PSMA-PET-CT.

Involved external institutions

How to cite

APA:

Meissner, S., Janssen, J.-C., Prasad, V., Diederichs, G., Hamm, B., Brenner, W., & Makowski, M.R. (2019). Accuracy of standard clinical 3T prostate MRI for pelvic lymph node staging: Comparison to 68 Ga-PSMA PET-CT. Scientific Reports, 9(1). https://doi.org/10.1038/s41598-019-46386-3

MLA:

Meissner, Sebastian, et al. "Accuracy of standard clinical 3T prostate MRI for pelvic lymph node staging: Comparison to 68 Ga-PSMA PET-CT." Scientific Reports 9.1 (2019).

BibTeX: Download