Development of a high-rate scalable readout system for gaseous detectors

Scharenberg L, Bortfeldt J, Brunbauer F, Christensen MJ, Desch K, Floethner K, Garcia F, Janssens D, Kaminski J, Lisowska M, Lupberger M, Muller H, Oliveri E, Orlandini G, Pfeiffer D, Ropelewski L, Rusu A, Samarati J, Schwaebig P, Van Stenis M, Veenhof R (2022)


Publication Type: Journal article

Publication year: 2022

Journal

Book Volume: 17

Journal Issue: 12

DOI: 10.1088/1748-0221/17/12/C12014

Abstract

The RD51 collaboration developed the Scalable Readout System (SRS) as part of its R & D activities on Micro-Pattern Gaseous Detectors. This common multi-purpose readout system allows to read out small R & D detectors (0.2k channels) up to mid-sized experiments with multiple detectors (2.5k to 5k channels). To cope with increased demands on detectors, electronics and readout speed, a new front-end ASIC-the VMM3a-was integrated into the SRS. This led to the development of a scalable, self-triggered high-rate readout system that provides energy, space and time information of the interacting particles at the same time.

Involved external institutions

How to cite

APA:

Scharenberg, L., Bortfeldt, J., Brunbauer, F., Christensen, M.J., Desch, K., Floethner, K.,... Veenhof, R. (2022). Development of a high-rate scalable readout system for gaseous detectors. Journal of Instrumentation, 17(12). https://dx.doi.org/10.1088/1748-0221/17/12/C12014

MLA:

Scharenberg, L., et al. "Development of a high-rate scalable readout system for gaseous detectors." Journal of Instrumentation 17.12 (2022).

BibTeX: Download