Quantification of epicardial adipose tissue by cardiac CT: Influence of acquisition parameters and contrast enhancement

Koenig S, Schreiber K, Ammon F, Göller M, Bittner D, Achenbach S, Hell M, Marwan M (2019)


Publication Type: Journal article

Publication year: 2019

Journal

Book Volume: 121

Article Number: 108732

DOI: 10.1016/j.ejrad.2019.108732

Abstract

Purpose: While computed tomography (CT) is frequently used to quantify epicardial adipose tissue (EAT), the effect of different acquisition parameters on EAT volume has not been systematically reported. We assessed the influence of low-voltage acquisition and contrast enhancement on EAT quantification. Method: Two independent cohorts (100 and 127 patients) referred for routine coronary CT were included. One cohort received a low-voltage and a standard voltage non-contrast acquisition (120 and 100 kV), the other cohort underwent non-contrast and contrast-enhanced CT. EAT volume was quantified using a semi-automated analysis software. Whereas the lower EAT threshold was consistently set at -190 Hounsfield Units (HU), different upper thresholds for EAT were analyzed. Bland-Altman analysis was used to analyze the agreement of EAT volume between scans with different acquisition parameters. We referred to a non-enhanced 120 kV acquisition with an upper threshold of -30 HU. Results: Mean EAT volume was 159 ± 76 ml as measured in 120 kV non-contrast data sets with an upper threshold of -30 HU. For 100 kV data sets, an upper threshold of -40 HU showed the best correlation (r = 0.961, p < 0.05). Significant overestimation was found for upper thresholds of -20 and -30 HU and significant underestimation for -50 HU. In non-contrast vs. contrast-enhanced acquisitions, there was a significant underestimation of EAT volume for contrast-enhanced scans (mean difference 31 ml, 95% limits of agreement 27 to −89 ml). Conclusions: CT-based EAT volume quantification in low-voltage and contrast-enhanced images is feasible. However, adjustment of the upper threshold for detection of fat is mandatory.

Authors with CRIS profile

How to cite

APA:

Koenig, S., Schreiber, K., Ammon, F., Göller, M., Bittner, D., Achenbach, S.,... Marwan, M. (2019). Quantification of epicardial adipose tissue by cardiac CT: Influence of acquisition parameters and contrast enhancement. European Journal of Radiology, 121. https://doi.org/10.1016/j.ejrad.2019.108732

MLA:

Koenig, Susanna, et al. "Quantification of epicardial adipose tissue by cardiac CT: Influence of acquisition parameters and contrast enhancement." European Journal of Radiology 121 (2019).

BibTeX: Download