Two-dimensional shear-wave elastography: a new method comparable to acoustic radiation force impulse imaging?

Schellhaas B, Strobel D, Wildner D, Görtz R, Neurath M, Pfeifer L (2017)


Publication Type: Journal article

Publication year: 2017

Journal

Book Volume: 29

Pages Range: 723-729

Journal Issue: 6

DOI: 10.1097/MEG.0000000000000846

Abstract

OBJECTIVES: Two-dimensional shear-wave elastography (2D-SWE) is an ultrasound-based technique for the noninvasive assessment of tissue stiffness. In contrast to the well-established point-shear-wave elastography (pSWE) method acoustic radiation force impulse imaging, there is little evidence on the performance and usefulness of 2D-SWE in the assessment of liver stiffness. Thus, the aim of our study was to compare 2D-SWE versus pSWE. MATERIALS AND METHODS: 2D-SWE and pSWE were performed in 20 cirrhotic patients, 20 healthy individuals and an elasticity phantom. Stiffness values, examination time and number of measurements were compared. For 2D-SWE, the influence of size of the region of interest (ROI) was assessed. RESULTS: Elastography values in healthy individuals were slightly higher for 2D-SWE versus pSWE (1.4 m/s, range: 1.21-1.68 vs. 1.23 m/s, range: 1.07-1.39). In cirrhotic patients, there were no significant differences (3.06 m/s, range: 1.83-5.35 vs. 3 m/s, range: 1.67-4.37 m/s). Examination times were significantly longer for 2D-SWE in both patient groups (mean values for healthy/cirrhotic patients: 129.6/157.1 vs. 75/71.6 s). For 2D-SWE, variation of ROI size (5, 10, 20 mm) produced comparable results. After eight measurements, 90% of cirrhotic patients showed less than 5% of deviation from the results after the gold standard of 10 measurements; for healthy individuals, this was observed after six measurements. CONCLUSION: 2D-SWE seems to be comparable to pSWE (acoustic radiation force impulse-imaging) in cirrhotic patients, with slightly higher values in healthy individuals. 2D-SWE measurements require considerably more time. For 2D-SWE, ROI size seems to be of minor importance; multiple measurements should be obtained as single measurements differ. These preliminary results should be confirmed in larger patient collectives with histology as the reference standard.

Authors with CRIS profile

How to cite

APA:

Schellhaas, B., Strobel, D., Wildner, D., Görtz, R., Neurath, M., & Pfeifer, L. (2017). Two-dimensional shear-wave elastography: a new method comparable to acoustic radiation force impulse imaging? European Journal of Gastroenterology & Hepatology, 29(6), 723-729. https://doi.org/10.1097/MEG.0000000000000846

MLA:

Schellhaas, Barbara, et al. "Two-dimensional shear-wave elastography: a new method comparable to acoustic radiation force impulse imaging?" European Journal of Gastroenterology & Hepatology 29.6 (2017): 723-729.

BibTeX: Download