Reproducibility of semi-automatic coronary plaque quantification in coronary CT angiography with sub-mSv radiation dose

Ovrehus KA, Schuhbaeck A, Achenbach S, Norgaard BL, Botker HE, Dey D, Marwan M (2016)


Publication Type: Journal article

Publication year: 2016

Journal

Book Volume: 10

Pages Range: 114-20

Journal Issue: 2

DOI: 10.1016/j.jcct.2015.11.003

Abstract

INTRODUCTION: Coronary computed tomographic angiography (CTA) can characterize coronary atherosclerotic plaque components as calcified and non-calcified. Quantitative measurements of coronary plaque burden by coronary CTA may play a role in serial studies to determine disease progression or response to medical therapies. The reproducibility from repeated assessment of such quantitative measurements from low-radiation dose coronary CTA has not been previously assessed. PURPOSE: To evaluate the interscan, interobserver and intraobserver reproducibility for coronary plaque volume assessment using semi-automatic plaque analyses algorithm in low radiation dose coronary CTA. METHODS: In 50 consecutive patients undergoing two 128-slice dual source CT scans within 12 days with a mean radiation dose of 0.7 mSv per coronary CTA, the interscan, interobserver and intraobserver reproducibility of coronary plaque assessment using validated software (AutoPlaq) were evaluated. RESULTS: Interscan, interobserver and intraobserver agreement for non-calcified and calcified plaque volumes were excellent (Spearman rho 0.87-0.99). Interscan mean percentage difference in non-calcified and calcified plaque volumes were 0.1% (p = 0.8) and 1.9% (p = 0.19) with limits of agreement of ±11% and ±48.5%; per inter- and intraobserver mean percentage differences were 0.1% (p = 0.25) and 0.3% (p = 0.001), and 0.3% (p = 0.33) and 0.4% (p = 0.59) with limits of agreement of ±7% and ±32.9%, and ±6.6% and ±32.1%, respectively. CONCLUSION: A semi-automatic plaque assessment algorithm in repeated low radiation dose coronary CTA allows for high reproducibility of coronary plaque characterization and quantification measures.

Authors with CRIS profile

Involved external institutions

How to cite

APA:

Ovrehus, K.A., Schuhbaeck, A., Achenbach, S., Norgaard, B.L., Botker, H.E., Dey, D., & Marwan, M. (2016). Reproducibility of semi-automatic coronary plaque quantification in coronary CT angiography with sub-mSv radiation dose. Journal of Cardiovascular Computed Tomography, 10(2), 114-20. https://doi.org/10.1016/j.jcct.2015.11.003

MLA:

Ovrehus, Kristian Altern, et al. "Reproducibility of semi-automatic coronary plaque quantification in coronary CT angiography with sub-mSv radiation dose." Journal of Cardiovascular Computed Tomography 10.2 (2016): 114-20.

BibTeX: Download