Schramm M, Hrobak M, Schür J, Schmidt LP, Konrad M (2015)
Publication Language: English
Publication Type: Conference contribution
Publication year: 2015
Publisher: Institute of Electrical and Electronics Engineers (IEEE)
DOI: 10.1109/eumc.2015.7345868
Due to the capabilities of modern vector network analyzers (VNAs), the usage of “True-Mode”-signals for characterizing and testing active differential devices is quite convenient. Nevertheless in cases, in which the device under test (DUT) and/or the measurement setup introduces a coupling between the required stimulus signals, current methods require some iteration time to achieve the desired phase and amplitude settings. In this paper a new approach will be introduced, which leads to an optimized testing time which can be crucial especially in industrial production test.
APA:
Schramm, M., Hrobak, M., Schür, J., Schmidt, L.-P., & Konrad, M. (2015). Optimized method for achieving accurate signals for “True-Mode” S-parameter measurements. In Proceedings of the 45$^{th}$ European Microwave Conference. Paris, FR: Institute of Electrical and Electronics Engineers (IEEE).
MLA:
Schramm, Marcus, et al. "Optimized method for achieving accurate signals for “True-Mode” S-parameter measurements." Proceedings of the 45$^{th}$ European Microwave Conference, Paris Institute of Electrical and Electronics Engineers (IEEE), 2015.