Will S (2005)
Publication Status: Published
Publication Type: Journal article, Original article
Publication year: 2005
Publisher: Elsevier
Book Volume: 182
Pages Range: 99-110
DOI: 10.1016/j.desal.2005.04.012
The knowledge of the CO release from the evaporating brine in multi-stage flash (MSF) and multiple-effect (ME) distillers is very important for the design, the operation, and the cost of desalination distillers as well as for the recarbonation of the distillate. The CO released in MSF plants can be used for the recarbonation of the distillate. The recarbonation method using CO from the vent gases of MSF plants has gained importance, since the post-treatment of potable water can be effected without additional CO production by combustion processes. The paper discusses if this approach may also be applied to ME distillers. The amounts of CO required for the recarbonation are compared with the amounts released. To this end, the CO release rates were calculated on the basis of two previously developed models. One consequence of the differences between MSF and ME systems regarding evaporation mechanisms, fluid flow, operating temperatures, and concentrations is that in MSF distillers the specific phase interface areas are lower and the mass transfer coefficients are higher compared to ME distillers. Consequently, the specific CO release in MSF plants is significantly higher than in ME plants. The total CO release in MSF recycle distillers amounts to about 82 g CO per ton of distillate at a top brine temperature of 100°C. The calculations show that, for the limestone/carbon dioxide method, MSF recycle distillers produce sufficient CO to allow recarbonation of the distillate up to an alkalinity of 187 ppm as CaCO at a top brine temperature of 100°C. The total CO release in ME distillers amounts to about 55 g CO per ton of distillate at a top brine temperature of 64°C. Utilizing the CO for the limestone recarbonation process would result in an alkalinity in the distillate of 124 ppm as CaCO. Provided that the alkalinity values aimed at in the distillate range from 50 to 80 ppm as CaCO, the calculations suggest that the CO release in ME distillers may be just sufficient in terms of stoichiometric consumption to allow for recarbonation using the limestone method. © 2005 Elsevier B.V. All rights reserved.
APA:
Will, S. (2005). The release of CO2 in MSF and ME distillers and its use for the recarbonation of the distillate: A comparison. Desalination, 182, 99-110. https://doi.org/10.1016/j.desal.2005.04.012
MLA:
Will, Stefan. "The release of CO2 in MSF and ME distillers and its use for the recarbonation of the distillate: A comparison." Desalination 182 (2005): 99-110.
BibTeX: Download