Buerhop C, Pickel T, Scheuerpflug H, Hauch J, Camus C, Brabec C (2017)
Publication Language: English
Publication Type: Conference contribution, Conference Contribution
Publication year: 2017
Pages Range: 2320 - 2324
ISBN: 3-936338-47-7
URI: http://www.eupvsec-proceedings.com/proceedings?paper=42495
DOI: 10.4229/EUPVSEC20172017-6BV.1.44
First statistical evaluation of IR-inspections of PV-plants reveals that 81% of the installed PV-plants show IR-abnormalities. More than 140 PV-plants with more than 200,000 PV-modules were inspected and evaluated statistically. Main IR-abnormalities or failures in modules and string installations are analyzed, respectively. The average failure rate for PV-modules is about 6% and for module strings approximately 1%. The differentiation based on the installation type reveals that small residential installations relatively seen show more defective modules than large field installations. A first estimation of the missed income by not detecting and maintaining major module and plant failures yield a missed income of about 100 Mio. EUR considering the PV-systems installed in Germany. IR-imaging is a valuable method to give fast and reliable information about the actual quality and failure rate in inspected PV-installations.
APA:
Buerhop, C., Pickel, T., Scheuerpflug, H., Hauch, J., Camus, C., & Brabec, C. (2017). Statistical Analysis of Infrared-Inspections of PV-Plants. In Proceedings of the 33rd European Photovoltaic Solar Energy Conference and Exhibition (pp. 2320 - 2324). Amsterdam, NL.
MLA:
Buerhop, Claudia, et al. "Statistical Analysis of Infrared-Inspections of PV-Plants." Proceedings of the 33rd European Photovoltaic Solar Energy Conference and Exhibition, Amsterdam 2017. 2320 - 2324.
BibTeX: Download